Evaluation of the dirt level of rotary and reciprocating systems after instrumentation and pre-sterilization cleaning procedures
DOI:
https://doi.org/10.5335/rfo.v26i2.13301Keywords:
limas, limpeza, reciprocante, rotatório, sujidade.Abstract
The aim of present study was to evaluate the dirt of rotary and reciprocating files after instrumentation and pre-sterilization cleaning procedures. Forty-four extracted human maxillary molars were included in the study. Twenty-four rotary files and 24 reciprocating files were randomly assigned to two main groups (n=24), according to the cleaning procedure after instrumentation: G1–hand washing and G2–ultrasonic washing. In each main group, there were subdivisions for the 24 files, as follows: SG1-rotary files without instrumentation; SG2–1 reciprocating file without instrumentation; SG3–2 rotary files submitted to instrumentation without cleaning protocol; SG4–2 reciprocating files files submitted to instrumentation without cleaning protocol; SG5– 10 rotary files submitted to instrumentation and cleaning protocol; SG6– 10 reciprocating files submitted to instrumentation and cleaning protocol. The analysis of dirt levels was performed by scanning electron microscopy (SEM), being the data submitted to the Kruskal-Wallis test, with a significance level of 5%. The lowest average of dirt between the experimental groups was found in SG5 of G1, with no significant difference when compared to the other groups (p>0.05). It could be concluded that cleaning protocols were not completely effective in removing dirt from endodontic files.
Downloads
References
Byström A, Sundqvist G. Bacteriologic evaluation of the efficacy of mechanical root canal instrumentation in endodontic
therapy. Scand J Dent Res 1981; 89(4):321-8.
Reiss-Araujo CJ, Araujo SS, Albuquerque DS, Rios MA, Portella ML. Limpeza em limas endodônticas pós-uso e pré-esterilização. RGO 2008; 56(1):17-20
Pereira BL, Oliveira MAVC, Biffi JCG. Avaliação da eficácia
de métodos de limpeza de limas endodônticas. Biosc J 2013;
(4):1058-63.
Gill DS, Tredwin CJ, Gill SK, Ironside JW. The transmissible
spongiform encephalopathies (prion diseases): a review for
dental surgeons. Int Dent J 2001; 51(6):439-46.
Popovic J, Gasis J, Zivkovic S, Petrovic A, Radicevic G. Evaluation of biological debris on endodontic instruments after
cleaning and sterilization procedures. Int Endod J 2010;
(4):336-41.
Morrison A, Conrod S. Dental burs and endodontic files: are
routine sterilization procedures effective? J Can Dent Assoc
; 75(1):39.
Murgel CAF, Walton RE, Rittman B, Pécora JD. A comparison of techniques for cleaning endodontic files after usage: a
quantitative scanning electron microscopic study. J Endod
; 16(5):214-7.
Linsuwanont P, Parashos P, Messer HH. Cleaning of rotary
nickel–titanium endodontic instruments. Int Endod J 2004;
(1):19-28.
Parashos P, Linsuwanont P, Messer HH. A cleaning protocol for rotary nickel–titanium endodontic instruments. Aust
Dent J 2004; 49(1):20-7.
Van Eldik DA, Zilm PS, Rogers AH, Marin PD. A SEM evaluation of debris removal from endodontic files aftercleaning and steam sterilization procedures. Aust Dent J 2004;
(3):128-35.
Souza MA, Menin MLF, Montagner F, Cecchin D, Farina AP.
SEM and microbiological analysis of dirt of endodontic files
after clinical use and your influence on sterilization process.
Dental Press Endod 2011; 1(1):16-21.
Peters OA, Barbakow F, Peters CI. An analysis of endodontic treatment with three nickel-titanium rotary root canal
preparation techniques. Int Endod J 2004; 37(12):849-59.
Castagna F, Rizzon P, da Rosa RA, Santini MF, Barreto MS,
Duarte MA, et al. Effect of passive ultrasonic instrumentation
as a final irrigation protocol on debris and smear layer removal - a SEM analysis. Microsc Res Tech 2013; 76(5):496-502.
Ribeiro EM, Silva-Sousa YT, Souza-Gabriel AE, Sousa-Neto
MD, Lorencetti KT, Silva SR. Debris and smear removal in
flattened root canals after use of different irrigant agitation
protocols. Microsc Res Tech 2012; 75(6):781-90.
Tanomaru Filho M, Leonardo MR, Bonifácio KC, Dametto
FR, Silva AB. The use of ultrasound for cleaning the surface of stainless steel and nickel-titanium endodontic instruments. Int Endod J 2001; 34(8):581-5.
Perakaki K, Mellor AC, Qualtrough AJ. Comparison of an
ultrasonic cleaner and a washer disinfector in the cleaning of
endodontic files. J Hosp Infect 2007; 67(4):355-9.
Queiroz MLP, Oliveira EPM, Borin G, Melo TAF. Eficácia de
diferentes técnicas na limpeza dos instrumentos endodônticos. RGO 2010; 58(3):369-73.
Downloads
Published
Issue
Section
License

This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.

This work is licensed under aCreative Commons Atribuição-NãoComercial-SemDerivações 4.0 Internacional.