Comparative study of the odontometric reliability of endodontic rulers of different brands

Authors

  • Bianca Maria de Melo Costa CENTRO UNIVERSITÁRIO DE JOÃO PESSOA
  • José Jhenikártery Maia de Oliveira CENTRO UNIVERSITÁRIO DE JOÃO PESSOA
  • Andreia Medeiros Rodrigues Cardoso UNIVERSIDADE FEDERAL DA PARAIBA
  • Manuela Gouvêa Campêlo dos Santos CENTRO UNIVERSITÁRIO DE JOÃO PESSOA
  • Rachel Reinaldo Arnaud UNIVERSIDADE FEDERAL DA PARAIBA
  • Sara Pires Dantas COESP
  • Nicole Fernandes Teixeira IPEO

DOI:

https://doi.org/10.5335/rfo.v30i1.16138

Keywords:

Dental Instruments, Endodontics, Odontometry

Abstract

Odontometry is the stage of endodontic treatment that determines the working limit for the endodontist. However, regardless of the method used, the millimetered endodontic ruler is a fundamental tool. Through it, the transfer of the working length is relayed to other instruments, avoiding possible measurement errors.To assess the accuracy and precision in measurements of millimetered endodontic rulers from different commercial brands for odontometry, in order to analyze their reliability in performing treatments. 50 rulers from five brands - Maquira, Angelus, KG Sorensen, Preven, and unbranded - were grouped, each with 10 samples. The measurement of 30 mm was pre-established as the target value to be found in all rulers when subjected to measurement analysis using a digital caliper. It is necessary for the professional to use the same ruler during the whole endodontic therapy in order to avoid errors while transferring measurements to the instruments and, as a result, jeopardize the success of the treatment.

Downloads

Download data is not yet available.

References

Maachar DF, Silva PG, Barros RMG, Pereira KFS. Avaliação da precisão do localizador apical Novapex: estudo in vitro. Rev. Odontol. Unesp 2008; 1: 41-46.

Lopes HP, Siqueira JF. Endodontia: Biologia e Técnica. 5 ed. Rio de Janeiro: Elsevier; 2020..

Lins PR, Menezes LVP, Araújo RPC, Silva SJA, Mendes CMC. Exatidão e precisão das réguas milimetradas utilizadas durante procedimentos endodônticos. Rev Ciênc Biol 2015.

Santos JF, Silva PAA. Confiabilidade odontométrica dos localizadores foraminais na terapia endodôntica. Revisão de literature. Rev Uningá 2018; 55:81-100.

Miranda LH, Dantas WCF, Mattar C. Técnicas avançadas de obturação endodôntica. Rev FAIPE 2017; 3: 46-60.

Oliveira MVL, Balbino CM, Souza MMT, Silvino ZR, Passos JP. Perfil, demanda de atendimento das intercorrências odontológicas e de retratação endodôntica. Revista Pró-UniverSUS; 2016; 7: 03-09

Kojima K, Inamoto K, Nagamatsu K, et al. Success rate of endodontic treatment of teeth with vital and nonvital pulps: a meta-analysis. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2004; 97:95 –9.

Peres AVS, Decurcio DA, Silva JAS, Morais ALG, Alencar AHG. Discrepância entre método convencional de odontometria com referência padrão. Rev Odontol Bras Central; 2010; 19:168-171.

Paiva HC, Borelli AL, Almeida MO, Sá DP, Akisue E, Santos RLO. Odontometria eletrônica em dentes decíduos: revisão de literatura e relato de caso. Rev da Faculdade de Odontologia de Porto Alegre. 2022; 63(1), 98-105.

Bolam M, Costa FLM, Barasuol JC, Felippe GS, Felippe MCS, Felippe WT. Estudo comparativo de três localizadores apicais eletrônicos na determinação do comprimento de trabalho. Dental Press Endod. 2018; 8:42-46.

Macêdo DT, Sousa IMMA, Lima LR, Falcão CAM, Feitosa GT. Padronização e exatidão de réguas endodônticas milimetradas. Research, Society and Development, 2023; 12(5).

Lima Júnior P, Silva MTX, Silveira FL, Veit EA. Laboratório de mecânica: subsídios para o Ensino de física experimental. Porto Alegre: UFRGS, Instituto de Física; 2015, 3-4 p.

Dadalti MTDSA, Dias BDM, Bruno AMV, Riso PDA. Precisão de réguas endodônticas milimetradas e orifício calibrador, e avaliação da regularidade da superfície do orifício calibrador. Dent. press endod. 2021; 40-45.

Victorino FR, Lustosa-Pereira A, Bernardineli N, Garcia RB, Moraes IG, Bramante CM. Analysis of accuracy of endodontic milimeter rulers of different commercial brands. Rev Gaúch Odontol. 2012; 60:305-308.

Yücel O, Saricam E, Altunkaynak B, Kayaoglu G. İki farklı endodontik cetvelin (endoblok) cetvel ve kalibrasyon deliklerinin ölçüm doÄŸruluklarının incelenmesi. Acta Odontologica Turcica 2020; 37:84-90.

Gonçalves MCW, Fontana CE, Stringheta CP, Bueno CES, Rocha DGP, Pinheiro SL, Pelegrini RA, Chiesa WMM, De Martin AS, Kato AS. Avaliação da acurácia de quatro localizadores apicais durante o retratamento endodôntico. Rev Assoc Paul Cir Dent. 2017; 71:36-40.

Published

2024-10-20

Issue

Section

Investigação Científica

How to Cite

Comparative study of the odontometric reliability of endodontic rulers of different brands. (2024). Revista Da Faculdade De Odontologia - UPF, 30(1). https://doi.org/10.5335/rfo.v30i1.16138